Hukseflux Thermal Sensors
Building thermal resistance measuring system with two measurement locations (USED)
Building thermal resistance measuring system with two measurement locations (USED)
Full working order, all sensors and wires are in perfect working order and condition. Case included.
TRSYS20 is a high-accuracy measuring system used in determining the in-situ thermal resistance (R-value), thermal conductance (Λ-value), and thermal transmittance (U-value) of building envelope components. The system is mostly used for measurements according to standard practices of ISO 9869, ASTM C1046 and ASTM C1155. TRSYS20 is equipped with high-resolution electronics, two heat flux sensors of model HFP01 as well as two pairs of matched thermocouples for differential temperature measurements. The high-sensitivity heat flux sensors combined with the robust, high-resolution electronics ensure that TRSYS20 continues making meaningful measurements when other systems no longer perform; in particular at very low heat fluxes and low temperature differences across the wall. The matched thermocouple pairs allow measurement of temperature differences with an uncertainty better than 0.1 °C over the entire temperature range. Two measurement locations provide redundancy allowing the user to verify that the measurement results are representative for the building envelope component.
Manufacturer Website - Click Here
| standards governing use | ISO 9869 ; ASTM C1046 ; ASTM C1155 |
| MCU graphical user interface | web page via web browser |
| heat flux sensors | |
| – measurand | heat flux (2 x) |
| – uncertainty of calibration | ± 3 % (k = 2) |
| – heat flux measurement resolution | 0.02 W/m² |
| – guard width to thickness ratio | 5 m/m (as required by ISO 9869 D.3.1) |
| TC matched thermocouple pair | |
| – measurand | temperature difference (2 x) |
| – accuracy | < ± 0.1 °C (as required by ISO 9869, paragraph 5.2) |
| – resolution | 0.02 °C |
| thermocouples | |
| – measurand | temperature (4 x) |
| – thermocouple type | IEC 60584-3: 2007 type KX |
| – tolerance class | Class II |
| required data analysis to determine building R-value and U-value | to be performed by the user according to ISO and ASTM standard practices |
| number of measurement locations | 2 |
| cable length per location | location 1: 10 m ; location 2: 20 m |
| rated operating temperature range HFP01 and TC | -30 to +70 °C |
| measurement duration range | > 3 days |
| data storage capacity | > 30 days |
| MCU specifications | |
| – connection | to local area network (LAN) via ethernet or directly to PC via USB |
| – supported web browsers | Chrome 10 ; Firefox 4 ; Internet Explorer 9 ; Opera 11 ;Safari 5 ; or later |
| – rated operating voltage MCU | 10 to 16 VDC |
| – ingress protection class | IP54 |
| PSU specifications | |
| – input voltage | 110-220 VAC, 50 / 60 Hz |
| – ingress protection class | IP22 |
Couldn't load pickup availability
Currently Out of Stock at Retail Storefront